Air Change Calculator for HEPA Air Scrubber

Use this air change calculator to find the airflow, the number of HEPA air scrubbers, or the air changes per hour (ACH) for an occupied space. Enter your room size and target air change rate, and you will see your results on screen in about a minute, with no sign-up needed.

  1. 1. Enter your spaceRoom dimensions, or the volume if you already know it.
  2. 2. Add your target ACHUse the number your project specifies, or tap a published example.
  3. 3. Get your airflow and unit countThen email yourself a detailed copy with planning notes.

This is a preliminary estimate to help you plan. Your facility or project engineer sets the final target and verifies the plan.

Units

1. Your space

Have more than one connected space? Add a row for each and we will add the volumes together.

2. Target air changes per hour (ACH)

ACH is how many times per hour the air in the space passes through the filters. Your target usually comes from your facility, project engineer or infection preventionist.

Not sure? These are published facility examples, not a requirement for your project. Tap one to fill it in.

All four are healthcare examples. We could not support examples for other building types with a published source, so for those, use the target your project specifies.

3. Your air scrubbers

This is the airflow rating on an air scrubber's label or spec sheet. Not sure? Leave it blank and we will show the total airflow you need, which you can match to any unit's rating.

More options

Only matters if you entered an airflow per unit. Label ratings are often higher than what a unit delivers on site.

Adds this much on top of the required airflow, for things like large openings or loaded filters. 100% doubles it. This is your own judgment, not a published factor. If a large opening leads to another space, adding that space as another room in section 1 is usually more accurate.

How to calculate air changes per hour

Air changes per hour (ACH), also called the air change rate, describes how many times per hour the air in a space passes through the filters. The calculator above uses two simple relationships:

ACH = CFM x 60 / room volume (cubic feet)CFM = ACH x room volume (cubic feet) / 60

In metric units, the airflow in cubic meters per hour equals ACH multiplied by the room volume in cubic meters.

Example: a room that is 30 ft long, 15 ft wide and 9 ft high holds 4,050 cubic feet. At a target of 6 ACH, the airflow needed is 6 x 4,050 / 60, which is 405 CFM. One air change takes 60 / 6, or 10 minutes.

If you have more than one connected space, add the volumes together, which is what the extra room rows in the calculator do.

How many air changes per hour do you need?

The target comes from your facility, your project engineer or your infection preventionist, not from this calculator. Published facility criteria vary. As examples only, a UC Davis Health document from 2025 and a Northwell Health document from 2024 each call for at least 4 ACH, a University of Virginia construction plan from 2025 lists at least 6 ACH for its recirculating option, and CDC guidance from 2003 describes portable recirculating HEPA units giving the equivalent of at least 12 ACH. These are healthcare examples, and they are not a requirement for your project. If your project specifies a number, use that one.

How to use this air change calculator

How many units do I need?

Enter your room size and target ACH. You will see the airflow you need. If you also enter the airflow rating of the air scrubber you plan to use, the calculator rounds up to a whole number of units.

Will my units be enough?

Enter your room size, the number of units and the airflow per unit. The calculator shows the ACH those units deliver and how long one air change takes.

Air change calculator questions

What does CFM mean?

CFM is cubic feet per minute, the airflow a unit moves. Multiply it by 60 to get cubic feet per hour, then divide by the room volume to get ACH.

Why does the unit count round up?

You cannot rent part of an air scrubber, and rounding down would leave you short of your target. The calculator always rounds up to the next whole unit.

What airflow number should I enter for a unit?

Use the most reliable number you have. A tested airflow for the assembled unit is better than a label rating, and airflow measured on site is better still. Label ratings are often higher than what a unit delivers once ducting is attached and filters load. If you are not sure, leave it blank and use the total airflow shown.

What does the extra capacity option do?

It adds a percentage on top of the required airflow, for things like large openings or loaded filters. It is your own judgment, not a published factor. If a large opening leads to another space, adding that space as another room is usually more accurate.

Does this calculator assess pressure?

No. It estimates airflow only. Room pressure, make-up air, leakage and mixing are separate questions, and they are set with your facility, project engineer or an industrial hygienist. Many jobs run some units recirculating and others exhausting to the outside, and the airflow math here is the same either way.

Need help planning containment?

Construction Containment Services provides temporary walls and air filtration for occupied spaces. Learn more about temporary walls or check out our guide to air scrubbers. To talk through your project, call (855) 684-3752 or email info@5dccs.com.